Omfattning
ISO 25539-1:2017 specifies requirements for the evaluation of endovascular systems (prostheses and delivery systems) and requirements with respect to nomenclature, design attributes and information supplied by the manufacturer based upon current medical knowledge. Guidance for the development of in vitro test methods is included in an informative annex to this document. This document can be considered as a supplement to ISO 14630, which specifies general requirements for the performance of non-active surgical implants.
ISO 25539-1:2017 is applicable to endovascular systems used to treat aneurysms, stenoses or other vascular anomalies or pathologies (e.g. dissections, transections) or to create shunts between vessels [e.g. creation of transjugular intrahepatic portosystemic shunting (TIPS)]. Some of the requirements are specific to endovascular treatment of arterial aneurysms or stenoses. Although uses of endovascular systems other than treatment of arterial aneurysms or stenoses (e.g. dissections, transections, shunts) are within the scope of this document, the specific requirements and testing are not described. Similarly, specific prosthesis configurations (e.g. fenestrated, branched) are within the scope, but specific requirements and testing are not described for these devices.
ISO 25539-1:2017 is not applicable to vascular occluders, with the exception of contra-lateral iliac artery occluders when used as an integral part of aorto-uni-iliac endovascular prosthesis. Although contra-lateral iliac artery occluders when used as an integral part of aorto-uni-iliac endovascular prosthesis are within the scope of this document, specific requirements and testing are not described for these devices.
Balloons used to achieve adequate apposition of the prosthesis with the vessel wall or overlapping components are within the scope of this document, even if they are not integral to the endovascular system. This document provides requirements beyond the requirement ...

Ämnesområden

Kirurgiska implantat, proteser och ortoser (11.040.40)


Köp denna standard

Standard Svensk standard · SS-EN ISO 25539-1:2017

Kardiovaskulära implantat - Endovaskulära produkter - Del 1: Endovaskulära proteser (ISO 25539-1:2017)
Prenumerera på standarden - Läs mer Dölj
Pris: 735 SEK
standard ikon pdf

PDF

Pris: 735 SEK
standard ikon

Papper

Pris: 1 176 SEK
standard ikon pdf + standard ikon

PDF + papper

Fler alternativ Färre alternativ

Produktinformation

Språk: Engelska

Framtagen av: Implantat, SIS/TK 340/AG 03

Internationell titel: Cardiovascular implants - Endovascular devices - Part 1: Endovascular prostheses (ISO 25539-1:2017)

Artikelnummer: STD-8025624

Utgåva: 3

Fastställd: 2017-03-22

Antal sidor: 150

Ersätter: SS-EN ISO 25539-1:2009/AC:2011 , SS-EN ISO 25539-1:2009