StandardSvensk standard
·
SS-EN ISO 80601-2-87:2021
Elektrisk utrustning för medicinskt bruk - Del 2-87: Särskilda krav på grundläggande säkerhet och väsentliga prestanda för högfrekvensventilatorer (ISO 80601-2-87:2021)
Status:
Gällande
Köp denna standard
StandardSvensk standard
·
SS-EN ISO 80601-2-87:2021
Elektrisk utrustning för medicinskt bruk - Del 2-87: Särskilda krav på grundläggande säkerhet och väsentliga prestanda för högfrekvensventilatorer (ISO 80601-2-87:2021)
Prenumerera på standarder med tjänst SIS Abonnemang. Genom att prenumerera får du effektiv åtkomst till gällande standarder och säkerställer att ditt företag alltid har tillgång till senaste utgåvan.
Läs mer om SIS Abonnemang
This document applies to the basic safety and essential performance of a high-frequency ventilator (HFV) in combination with its accessories, hereafter referred to as ME equipment:
- intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare facility;
NOTE 1 For the purposes of this document, such an environment is referred to as a critical care environment. High-frequency ventilators for this environment are considered life-sustaining.
NOTE 2 For the purposes of this document, such a high-frequency ventilator can provide transport within a professional healthcare facility (i.e., be a transit-operable ventilator).
NOTE 3 A high-frequency ventilator intended for use in transport within a professional healthcare facility is not considered as a ventilator intended for the emergency medical services environment.
- intended to be operated by a healthcare professional operator;
- intended for those patients who need differing levels of support from artificial ventilation including ventilator-dependent patients; and
- capable of providing more than 150 inflations/min.
There are three principal designations of HFV:
- high-frequency percussive ventilation [HFPV, with a typical HFV frequency of (60 to 1 000) HFV inflations/min];
- high-frequency jet ventilation [HFJV, with a typical HFV frequency of (100 to 1 500) HFV inflations/min]; and
- high-frequency oscillatory ventilation [HFOV, with a typical HFV frequency of (180 to 1200) HFV inflations/min and typically having an active expiratory phase].
Additionally, HFV designations can be combined together or with ventilation at rates less than 150 inflations/min.
* A high-frequency ventilator is not considered a physiologic closed loop-control system unless it uses a physiological patient variable to adjust the ventilation therapy settings.
This document is also applicable to those accessories intended by their manufacturer to be connected to an HFV breathing system, or to a high-frequency ventilator, where the characteristics of those accessories can affect the basic safety or essential performance of the high-frequency ventilator.
If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.
Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of IEC 60601-1:2005.
NOTE 4 Additional information can be found in 4.2 of IEC 60601-1:2005+AMD1:2012.
This document is not applicable to ME equipment that is intended solely to augment the ventilation of spontaneously breathing patients within a professional healthcare facility.
This document does not specify the requirements for:
- non-high-frequency ventilators or accessories which provide conventional ventilation for use in critical care environments, which are given in ISO 80601-2-12 [23];.
NOTE 5 An HFV can incorporate conventional critical care ventilator operational modes, in which case ISO 80601- 2-12 is applicable to those modes.
- ventilators or accessories intended for anaesthetic applications, which are given in
ISO 80601-2-13 [24];
- ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601-2-84, the replacement for ISO 10651-3 [13];
NOTE 6 An HFV can incorporate EMS ventilator capability.
- ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601-2-72 [26];
- ventilators or accessories intended for home-care ventilatory support devices, which are given in ISO 80601-2-79 [27] and ISO 80601-2-80 [28], the replacements for ISO 10651-6 [15];
- sleep apnoea breathing therapy ME equipment, which are given in ISO 80601-2-70 [25];
- bi-level positive airway pressure (bi-level PAP) ME equipment;
- continuous positive airway pressure (CPAP) ME equipment;
- respiratory high-flow ME equipment, which are given in ISO 80601-2-90:—1; and
- cuirass or “iron-lung” ventilation equipment.
This document is a particular standard in the IEC 60601 series, the IEC 80601 series and the ISO 80601 series.
StandardSvensk standard
·
SS-EN ISO 80601-2-87:2021
Elektrisk utrustning för medicinskt bruk - Del 2-87: Särskilda krav på grundläggande säkerhet och väsentliga prestanda för högfrekvensventilatorer (ISO 80601-2-87:2021)
Prenumerera på standarder med tjänst SIS Abonnemang. Genom att prenumerera får du effektiv åtkomst till gällande standarder och säkerställer att ditt företag alltid har tillgång till senaste utgåvan.
Läs mer om SIS Abonnemang
Internationell titel: Medical electrical equipment - Part 2-87: Particular requirements for basic safety and essential performance of high-frequency ventilators (ISO 80601-2-87:2021)
Artikelnummer: STD-80028976
Utgåva: 1
Fastställd: 2021-05-04
Antal sidor: 148
Inom samma område
Varorna och tjänsterna som listas nedan ligger i samma ämnesområde (ICS-kod).