Standard Svensk standard · SS-EN ISO 10703:2015

Water quality - Determination of the activity concentration of radionuclides - Method by high resolution gamma-ray spectrometry (ISO 10703:2007)

Status: Upphävd

· Ersätts av: SS-EN ISO 10703:2021
Köp denna standard

Standard Svensk standard · SS-EN ISO 10703:2015

Water quality - Determination of the activity concentration of radionuclides - Method by high resolution gamma-ray spectrometry (ISO 10703:2007)
Prenumerera på standarden - Läs mer Dölj
Pris: 1 013 SEK
standard ikon pdf

PDF

Pris: 1 013 SEK
standard ikon

Papper

Pris: 1 620,80 SEK
standard ikon pdf + standard ikon

PDF + papper

Fler alternativ Färre alternativ
Provläs denna standard
Omfattning
This International Standard specifies a method for the simultaneous determination of the activity concentration of various radionuclides emitting gamma rays with energies 40 keV NOTE The determination of the activity concentration of radionuclides emitting gamma rays with energy below 40 keV and above 2 MeV is also possible within the scope of this International Standard, provided both the calibration of the measuring system and the shielding are adapted to this purpose. This International Standard includes the procedures for energy calibration, determination of the energy dependent sensitivity of the measuring system, the analysis of the spectra and the determination of the activity concentration of the various radionuclides in the sample studied. It is only applicable to homogeneous samples. Samples with activities typically between 1 Bq and 104 Bq can be measured as such, i.e. without dilution or concentration of the sample or special (electronic) devices. Depending on different factors, such as the energy of the gamma rays and the emission probability per nuclear disintegration, the size and geometry of the sample and the detector, the shielding, the counting time and other experimental parameters, the sample should be concentrated by evaporation when activities below about 1 Bq have to be measured. Also, when the activity is considerably higher than 104 Bq, the sample should be either diluted or an aliquot of the sample should be taken or the source to detector distance should be increased, or a correction for pile-up effects should be applied.

Ämnesområden

Undersökning av vattens fysikaliska egenskaper (13.060.60) Strålningsmätning (17.240)


Köp denna standard

Standard Svensk standard · SS-EN ISO 10703:2015

Water quality - Determination of the activity concentration of radionuclides - Method by high resolution gamma-ray spectrometry (ISO 10703:2007)
Prenumerera på standarden - Läs mer Dölj
Pris: 1 013 SEK
standard ikon pdf

PDF

Pris: 1 013 SEK
standard ikon

Papper

Pris: 1 620,80 SEK
standard ikon pdf + standard ikon

PDF + papper

Fler alternativ Färre alternativ

Produktinformation

Språk: Engelska

Framtagen av: Kemiska vattenundersökningar, SIS/TK 424

Internationell titel: Water quality - Determination of the activity concentration of radionuclides - Method by high resolution gamma-ray spectrometry (ISO 10703:2007)

Artikelnummer: STD-8016715

Utgåva: 1

Fastställd: 2015-10-19

Antal sidor: 36

Ersätts av: SS-EN ISO 10703:2021